Every calculation Timbral can perform is catalogued in the database below. Each entry gives a plain-language description, the equation as the app applies it, its inputs and units, a worked example (verified against Timbral’s own calculation code and the original reference spreadsheet), and the standard or source it comes from where one is cited.
How to use this reference
- Use the By Family view to browse calculations the way they are grouped in the ribbon (Propagation, Mechanical, and so on).
- Use the By Standard view to see everything drawn from a particular standard (ISO 9613-2, CIBSE Guide B4, BS 8233, …).
- Click any entry to open its full page.
A note on sign convention: attenuation and sound-reduction values are shown as negative dB (see the sign-convention note on the guide’s home page).
Band Conversion
- =ABSORPTIONTHIRDTOOCTAVE — α 1/3 → 1/1
- =SRITHIRDTOOCTAVE — SRI 1/3 → 1/1
- =SUMTHIRDTOOCTAVE — Levels 1/3 → 1/1
Building Acoustics
- Composite Transmission Loss
- Inside-to-Outside Noise Transfer
- Lp,rev from V and RT (Reverberant SPL)
- Mass Law — Sound Reduction Index
- NS 8178 Reverberation Time Limits
- Outside → Inside — Facade Attenuation (BS 8233:2014 Appendix G)
- Room Constant
- Room Mode Frequency
- Room-to-Room Sound Transfer
- RT from Alpha
- RT from Sabines — Eyring Reverberation Time
- RT from Sabines — Sabine Reverberation Time
- Sabines from RT (Sabine Absorption Area)
- Schroeder Frequency
- SPL in Room (Direct + Reverberant)
Curves
- Absorption Class Curve Fill (A–E)
- G Curve Fill
- ISO 226 Equal-Loudness Contour Fill
- ISO 389-7 Hearing Threshold Fill
- NR Curve Fill
- Weighting Curve Fill (A / B / C / D / R / H / Z)
dB Arithmetic
- =BGCORRECT — Background Noise Correction
- =DBADD — Decibel Sum
- =DBAVG — Decibel Average
- =DBSUB — Decibel Subtraction
Environmental
Mechanical
- Attenuator Noise Break-in
- Blade Passage Frequency
- Ceiling Plenum Breakout
- Circular Duct Breakout
- Crosstalk in-duct SWL
- Duct Bend Attenuation
- Duct run
- End Reflection Loss
- Fan Sound Power Level
- Junction/Split
- Lined Flexible Duct
- Louvre Angle (outdoors)
- Outlet directivity (indoors)
- Outlet to receiver (Direct + Reverberant, from RT)
- Outlet to receiver (Internal)
- Plantroom Louvre
- Rectangular Duct Break-in
- Rectangular Duct Breakout
- Straight Duct Attenuation
Physics Utilities
Propagation
- Conformal Area Propagation
- Line Source — Distance Attenuation
- Line Source — Power to Pressure
- Parallelipiped Area Propagation
- Plane Source — Distance Attenuation
- Point Source — Distance Attenuation
- Point Source — Power to Pressure
Ratings
- A-Weighted Total
- Absorption Class (A–E)
- B / C / D / R / H-Weighted Totals
- G-Rating (Gym Acoustics)
- NC (Noise Criterion)
- NR (Noise Rating)
- Rw / Dw / DnT,w (C; Ctr) — Weighted Sound Reduction Index
- Tmf / T(125–4 kHz) — Mean Reverberation Time
- Z-Weighted Total
- αw — Weighted Sound Absorption Coefficient