Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

ISO 9613-2 Atmospheric Absorption

Formula
Aatm = αatm·d/1000, αatm (dB/km) from ISO 9613-1 at the exact band centre frequency
Output
dB (negative = attenuation)
Bands
63 Hz – 8 kHz
Standard / Source
ISO 9613-2:2024
Access
Toolbar block

What it does

Calculates the attenuation due to atmospheric absorption over a propagation distance, ISO 9613-2:2024 clause 7.2, with the absorption coefficient computed from ISO 9613-1 for the air temperature, relative humidity and pressure you give.

Equation

Aatm=αatm d1000A_{atm} = \frac{\alpha_{atm}\,d}{1000}

with αatm in dB/km from ISO 9613-1 Formula (5), evaluated at the exact mid-band frequency fm=1000⋅103n/10f_m = 1000\cdot10^{3n/10} Hz (63 Hz → 63.10 Hz, 8 kHz → 7943 Hz):

α=8.686 f2[1.84×10−11(papr)−1(TT0)1/2+(TT0)−5/2(0.01275 e−2239.1/TfrO+f2/frO+0.1068 e−3352/TfrN+f2/frN)]\alpha = 8.686\,f^2\left[1.84\times10^{-11}\left(\frac{p_a}{p_r}\right)^{-1}\left(\frac{T}{T_0}\right)^{1/2} + \left(\frac{T}{T_0}\right)^{-5/2}\left(\frac{0.01275\,e^{-2239.1/T}}{f_{rO} + f^2/f_{rO}} + \frac{0.1068\,e^{-3352/T}}{f_{rN} + f^2/f_{rN}}\right)\right]
frO=papr(24+4.04×104 h 0.02+h0.391+h),frN=papr(TT0)−1/2(9+280 h e−4.170[(T/T0)−1/3−1])f_{rO} = \frac{p_a}{p_r}\left(24 + 4.04\times10^4\,h\,\frac{0.02 + h}{0.391 + h}\right),\qquad f_{rN} = \frac{p_a}{p_r}\left(\frac{T}{T_0}\right)^{-1/2}\left(9 + 280\,h\,e^{-4.170\left[(T/T_0)^{-1/3} - 1\right]}\right)
h=hr psat/prpa/pr,psatpr=10−6.8346 (T01/T)1.261+4.6151h = h_r\,\frac{p_{sat}/p_r}{p_a/p_r},\qquad \frac{p_{sat}}{p_r} = 10^{-6.8346\,(T_{01}/T)^{1.261} + 4.6151}

with T in kelvin, T0 = 293.15 K, T01 = 273.16 K and pr = 101.325 kPa (ISO 9613-1 Annex B).

ℹ️ Evaluating at the exact centre frequencies is what reproduces ISO 9613-2's Table 2; nominal frequencies do not. A relative humidity that is blank or 0 % gives no result (with the reason), rather than computing silently. Bands 63 Hz – 8 kHz (31.5 Hz is below ISO 9613-1's stated accuracy range). Timbral writes the result negative (an attenuation).

Inputs

InputMeaningUnitExample
Tair temperature°C10
hrrelative humidity (above 0, up to 100)%70
paatmospheric pressure (must be greater than 0)kPa101.325
dpropagation distance (must be greater than 0)m500

Worked example

10 °C, 70 % relative humidity, 101.325 kPa (ISO 9613-2's reference conditions), d = 500 m:

Band (Hz)631252505001000200040008000
αatm (dB/km)0.120.411.041.933.669.6632.77116.88
Result (dB)−0.06−0.21−0.52−0.96−1.83−4.83−16.39−58.44

The coefficients agree with ISO 9613-2 Table 2 (0.1, 0.4, 1.0, 1.9, 3.7, 9.7, 32.8, 117 dB/km at 10 °C and 70 %).

Source

ISO 9613-2:2024 — clause 7.2, Formula (9); ISO 9613-1:1993 — Formulae (3)–(6) and Annex B. Bands 63–8000 Hz.

Register interest