- Formula
- Lp,rev = Lw − 10·log₁₀(V) + 10·log₁₀(RT) + 14 + 10·log₁₀(N)
- Output
- dB — reverberant SPL per band
- Bands
- Follows the input spectra
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Estimates the reverberant-field sound pressure level in a room produced by one or more sources of known sound power, given the room volume and reverberation time. This is the diffuse-field level away from any single source, e.g. the general level inside a plantroom. Ribbon: Buildings → Lp,rev from V and RT.
Equation
with V the room volume, RT the reverberation time (per band), and N the number of identical sources. A band whose RT is blank or zero is left blank.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Lw | source sound power level (a spectrum row) | dB | 90 |
| RT | reverberation time (a spectrum row) | s | 0.75 |
| V | room volume | m³ | 200 |
| N | number of sources | — | 1 |
Worked example
At 63 Hz — Lw = 90 dB, RT = 0.75 s, V = 200 m³, N = 1:
Source
Standard diffuse-field (reverberant) level relation. No specific published standard is cited in the software.