Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

Vibration Converter

Formula
Convert displacement/velocity/acceleration, dB ↔ linear, via ω = 2πf
Output
dB or SI unit (depends on selected output), per band
Bands
Follows the input spectrum
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

Converts a row of vibration levels between displacement, velocity and acceleration, and between dB and linear representation, at each band — e.g. turning a measured acceleration spectrum in dB into linear displacement for use elsewhere. Conversion between quantities uses ω = 2πf, so it is frequency-dependent even though the dB↔linear step alone is not.

Equation

dB → linear: x=xref⋅10dB/20x = x_{ref}\cdot 10^{dB/20}, with reference values 10⁻¹² m (displacement), 10⁻⁹ m/s (velocity), 10⁻⁶ m/s² (acceleration).

Between quantities, via displacement: disp=vel/ω=accel/ω2\text{disp} = \text{vel}/\omega = \text{accel}/\omega^2, then back out to the target quantity, where ω = 2πf.

Inputs

InputMeaningUnitExample
Sourcevibration levels (a spectrum row)—see below
Input quantityquantity/representation of the source row (select)—Acceleration (dB re 10⁻⁶ m/s²)
Output quantityquantity/representation to convert to (select)—Displacement (dB re 10⁻¹² m)

Worked example

Acceleration in dB re 10⁻⁶ m/s² → Displacement in dB re 10⁻¹² m:

Band (Hz)1631.563
Accel in (dB)707580
Disp out (dB)109.9103.196.1

Source

Standard vibration-quantity and dB-reference conversions (reference values per ISO 8041 / common practice for building vibration). No specific published standard is cited in the software for the conversion logic itself.

Register interest

Tell us a little about you and we'll be in touch when Timbral is ready.