- Formula
- Dz = 10·log₁₀(1 + (2 + (C₂/λ)·C₃·z)·Kmet), max 20 dB (25 dB over two edges); Abar = Dz − Agr (Agr > 0)
- Output
- dB (negative = attenuation), capped at −20 dB (one edge) or −25 dB (two edges); second row: insertion loss Abar
- Bands
- 63 Hz – 8 kHz (31.5 Hz is outside ISO 9613-2's scope)
- Standard / Source
- ISO 9613-2:2024
- Access
- Toolbar block
What it does
Estimates the screening attenuation a solid barrier provides between a source and a receiver, band by band, from the way sound diffracts over the barrier's top, per ISO 9613-2:2024 clause 7.4. The deeper the acoustic "shadow" — i.e. the longer the detour up and over the barrier compared with the straight source-to-receiver line — and the higher the frequency, the more attenuation, up to 20 dB over one edge or 25 dB over two.
A Diffracting edges switch handles one thin screen or two edges (a thick barrier's two top corners, or two separate screens). The block has two result rows: the barrier attenuation Dz and, when you supply the ground attenuation without the barrier, the barrier insertion loss Abar.
Equation
The attenuation depends on the signed path-length difference z between the path over the barrier and the direct line of sight (positive when the barrier breaks the line of sight):
with wavelength (c = 343 m/s by default; ISO 9613-2 quotes 340 m/s, about 0.05 dB different), (ground reflections included; 40 where they are modelled separately by image sources), and:
- C₃ = 1 for one edge; over two edges a distance e apart (Formula 20):
- Kmet, the downwind correction (Formula 21), or 1 if you choose "Kmet = 1":
where a and b are the distances from the source to the (first) edge and from the (last) edge to the receiver, and d the direct distance. The result is written negative and capped at −20 dB (one edge) or −25 dB (two edges).
Insertion loss (Formulae 16/17): where , else ; never below 0. Agr is the ground attenuation with the barrier removed — link the ISO 9613-2 Ground Attenuation result row.
ℹ️ Bands 63 Hz – 8 kHz: 31.5 Hz is outside ISO 9613-2's scope, so it is left blank (a block saved with a 31.5 Hz value loses it on its next recalc). A block saved before these options existed computes as one edge, Kmet = 1, C₂ = 20, c = 343 m/s, exactly as before.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Hs | source height above ground | m | 2 |
| Hr | receiver height above ground | m | 1.5 |
| Hb | height of the (first) diffracting edge above ground | m | 3 |
| ds | source → (first) edge distance | m | 10 |
| dr | (last) edge → receiver distance | m | 15 |
| Diffracting edges | single edge or two edges | select | single edge |
| eh, Hb2 | distance between the edges and height of the second edge (two edges only) | m | 2, 3 |
| Kmet | Formula (21) or 1 | select | Formula (21) |
| C₂ | 20 (ground reflections included) or 40 (modelled separately) | select | 20 |
| c | speed of sound | m/s | 343 |
| Agr (optional) | ground attenuation without the barrier, Timbral's sign (a row) | dB | — |
Worked example
With the geometry above (signed path difference z = 0.120 m):
| Band (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|
| Kmet = 1 (dB) | −5.37 | −5.88 | −6.76 | −8.12 | −9.99 | −12.29 | −14.90 | −17.70 |
| Kmet per Formula (21) (dB) | −5.28 | −5.77 | −6.62 | −7.94 | −9.77 | −12.05 | −14.65 | −17.43 |
| Two edges, e = 2 m, Hb2 = 3 m (dB) | −5.28 | −5.77 | −6.69 | −8.37 | −11.32 | −15.16 | −18.75 | −21.94 |
(At 1 kHz with Formula (21): λ = 0.343 m, Kmet = 0.9461, Dz = 9.8 dB. Over two edges C₃ = 1.624 and Kmet = 0.9380 at 1 kHz, so Dz = 11.3 dB; at 8 kHz the two-edge result passes the one-edge 20 dB ceiling only because its own cap is 25 dB.)
Higher frequencies are screened more effectively — a barrier is far better at attenuating a whine than a rumble.
Source
ISO 9613-2:2024 — clause 7.4: barrier attenuation (capped at 20 dB for one edge, 25 dB for two), C₃ Formula (20), Kmet Formula (21), insertion loss Abar Formulae (16)/(17). Speed of sound 343 m/s by default. Bands 63–8000 Hz.