Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

B / C / D / R / H-Weighted Totals

Formula
dB(X) = 10·log₁₀( Σ 10^((Lᵢ + Xᵢ)/10) ), X = B, C, D, R or H weighting
Output
dB(B) / dB(C) / dB(D) / dB(R) / dB(H) — single figure
Bands
Summarises the bands of the row that the curve defines (B, D, R, H: 25 Hz – 10 kHz; C: 10 Hz – 10 kHz, and below on the LF sheet)
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block, Inline =function

What it does

The siblings of A-Weighted Total: each collapses a spectrum into a single weighted level using a different frequency-weighting curve — B, C, D, R or H. The correction for each band is added to its level, then the bands are energy-summed. (For the unweighted total see Z-Weighted Total.)

A band the chosen curve has no correction for (B, D, R and H have none below 25 Hz) is left out of the sum rather than rejected, so a low-frequency row is weighted over the bands the curve covers.

Equation

LX=10 log⁡10 ⁣(∑i10(Li+Xi)/10)L_{X} = 10\,\log_{10}\!\left(\sum_i 10^{(L_i + X_i)/10}\right)

where XiX_i is the band correction of curve X (see Weighting Curve Fill (A / B / C / D / R / H / Z) for the values). The octave corrections are:

Band (Hz)31.5631252505001000200040008000
B−17.1−9.3−4.2−1.3−0.30−0.1−0.7−2.9
C−3.0−0.8−0.2000−0.2−0.8−3.0
D−16.7−10.9−5.5−1.6−0.307.911.15.5
R−100−100−100−71−55−26−20−130
H−56−35−21−12−6−504−15

How to use it

  • From the ribbon — select the spectrum row(s) and choose Ratings → Weightings → Overall dB(B) (or dB(C), dB(D), dB(H), dB(R)). This writes e.g. =DBC(range, anchor) into each row's Rating column (click again to remove it) — no dialog, no inserted calc block. Several weightings can share one Rating cell, one per line.
  • As a function — =DBB(range), =DBC(range), =DBD(range), =DBR(range), =DBH(range) (returns e.g. 92.5 dB(C)). The pre-rename spellings BWEIGHTRATING / CWEIGHTRATING / DWEIGHTRATING / RWEIGHTRATING / HWEIGHTRATING still work. An optional trailing "dp:2" sets the decimal places (default 1).

Inputs

InputMeaningUnitExample
Spectrumoctave- or 1/3-octave-band levelsdBsee below

Worked example

The same spectrum as the A- and Z-weighted entries, [31.5: 78, 63: 85, 125: 91, 250: 83, 500: 78, 1000: 65, 2000: 64, 4000: 62, 8000: 55] dB:

CurveBCDRH
Total88.6 dB(B)92.5 dB(C)87.9 dB(D)56.3 dB(R)76.6 dB(H)

(For comparison, 79.9 dB(A) and 92.8 dB(Z). C-weighting barely discounts the loud 125 Hz band, so dB(C) sits close to dB(Z); R-weighting all but removes everything below 250 Hz.)

Source

C: IEC 61672-1 (tabulated 10 Hz – 10 kHz). B and D: historical curves that are not part of IEC 61672-1 (they were dropped after IEC 60651); no values are given below 25 Hz. R and H: bespoke, non-standard Timbral curves, with no published values below 25 Hz. Energy summation as standard.