- Formula
- Arithmetic mean of the octave-band reverberation times over the range
- Output
- s — e.g. Tmf(500-2kHz) 0.63 s, T(125-4kHz) 0.68 s
- Bands
- Tmf: 500 Hz – 2 kHz; T: 125 Hz – 4 kHz (octave; 1/3-octave input averaged to octaves first)
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block, Inline =function
What it does
Summarises a reverberation-time spectrum as a single figure: Tmf, the mean over the 500 Hz, 1 kHz and 2 kHz octave bands (the usual UK mid-frequency reverberation time, as in BB93), or T(125–4 kHz), the mean over the six octave bands from 125 Hz to 4 kHz. Use them from the Ratings ribbon, or type =TMFMID(E5:M5, 31.5) or =RTMEAN(E5:M5, 31.5) into a cell.
Equation
- Reverberation times are averaged, never added in dB.
- On a 1/3-octave row each octave is first the mean of its 1/3-octave bands, so every octave carries equal weight.
- A blank or zero band is unmeasured, not 0 s: it is left out and the mean is taken over the bands that have a value. A negative value is an error.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| T | reverberation time spectrum (a row) | s | see below |
Worked example
| Band (Hz) | 125 | 250 | 500 | 1000 | 2000 | 4000 |
|---|---|---|---|---|---|---|
| T (s) | 0.9 | 0.8 | 0.7 | 0.6 | 0.6 | 0.5 |
Tmf = (0.7 + 0.6 + 0.6) / 3 = 0.63 s; T(125–4 kHz) = (0.9 + 0.8 + 0.7 + 0.6 + 0.6 + 0.5) / 6 = 0.68 s.
Source
The arithmetic mean of the octave-band reverberation times; the 500 Hz – 2 kHz range is the mid-frequency reverberation time Tmf used in UK school acoustics guidance (BB93).