Time Correction

Formula
Correction = 10·log₁₀(T / T₀)
Output
dB (single value)
Bands
Scalar (not a spectrum)
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

Gives the time correction needed to normalise a sound level measured over one time period to an equivalent level over a different reference period — e.g. adjusting a short sample measurement onto a standard 1-hour or day/night reference.

Equation

Correction=10 log⁡10 ⁣(TT0)\text{Correction} = 10\,\log_{10}\!\left(\frac{T}{T_0}\right)

Inputs

InputMeaningUnitExample
Tactual sample time periods10
T₀reference time periods3600

Worked example

T = 10 s, T₀ = 3600 s:

10 log⁡10(10/3600)=−25.6 dB10\,\log_{10}(10/3600) = -25.6\ \text{dB}

Source

Standard logarithmic time-averaging relationship. No specific published standard is cited in the software.