- Formula
- Agr = −10·lg[1 + (10^(−A′gr/10) − 1)·Kgeo], A′gr = AS + AR + Am (ISO 9613-2:2024 7.3.1, Table 3)
- Output
- dB (negative = attenuation; positive = ground gain)
- Bands
- 63 Hz – 8 kHz (Table 3 has no 31.5 Hz row)
- Standard / Source
- ISO 9613-2:2024
- Access
- Toolbar block
What it does
Calculates the ground attenuation Agr between a source and a receiver over flat (or constant-slope) ground, downwind, by the general method of ISO 9613-2:2024 clause 7.3.1. The ground is split into a source region, a middle region and a receiver region, each with its own ground factor G (0 = hard, 1 = porous).
Equation
- AS, AR — the source and receiver region terms from Table 3, per band: −1.5 at 63 Hz; −1.5 + G·a′(h), b′(h), c′(h), d′(h) at 125, 250, 500, 1000 Hz; −1.5(1 − G) at 2–8 kHz, with G and h the region's ground factor and height.
- Am — the middle region term: −3q at 63 Hz, −3q(1 − Gm) above, with q = 0 when dp ≤ 30(hS + hR), else q = 1 − 30(hS + hR)/dp.
- The height functions (Table 3):
ℹ️ The source region extends 30·hS from the source and the receiver region 30·hR back from the receiver (each at most dp); the middle region is the rest. G for each region is an input: averaging a mixed region (Formula 10) is up to you. Timbral writes the result as −Agr, so a ground gain (negative Agr) shows positive. Bands 63 Hz – 8 kHz only.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| hS | source height | m | 1.5 |
| hR | receiver height | m | 4 |
| dp | source–receiver distance projected onto the ground plane (must be greater than 0) | m | 200 |
| GS, Gm, GR | ground factor of the source, middle and receiver regions (0–1; blank reads as 0, hard) | — | 0, 0.5, 1 |
Worked example
hS = 1.5 m, hR = 4 m, dp = 200 m, GS = 0, Gm = 0.5, GR = 1. Then q = 1 − 30 × 5.5 / 200 = 0.175 and Kgeo = 0.9994.
| Band (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|
| AS (dB) | −1.50 | −1.50 | −1.50 | −1.50 | −1.50 | −1.50 | −1.50 | −1.50 |
| AR (dB) | −1.50 | 2.76 | 2.00 | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 |
| Am (dB) | −0.53 | −0.26 | −0.26 | −0.26 | −0.26 | −0.26 | −0.26 | −0.26 |
| Agr (dB) | −3.52 | 0.99 | 0.24 | −1.75 | −1.76 | −1.76 | −1.76 | −1.76 |
| Result, −Agr (dB) | 3.5 | −1.0 | −0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 |
(e.g. at 125 Hz: AR = −1.5 + 1 × a′(4) = −1.5 + 4.26 = 2.76 dB; A′gr = −1.50 + 2.76 − 0.26 = 0.99 dB.)
Source
ISO 9613-2:2024 — clause 7.3.1 (general method), Formulae (11)–(13) and Table 3. Bands 63–8000 Hz.