Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

Room Constant

Formula
Rc = A / (1 − A/S) = S·α_avg / (1 − α_avg)
Output
m² — room constant per band
Bands
Follows the absorption spectrum
Standard / Source
SRL — Noise Control in Building Services
Access
Toolbar block

What it does

Gives the room constant Rc — a measure of a room's total absorptive capacity relative to its size, used as the reverberant-field term in calcs such as SPL in Room and Reverberant SPL. A larger Rc means a more absorptive (less reverberant) room. Ribbon: Buildings → Reverberation → Room Constant.

Equation

Rc=A1−A/SR_c = \frac{A}{1 - A/S}

where A is the per-band equivalent absorption area (m²) and S is the total room surface area (m²). If A ≥ S (a fully absorptive room) Rc is returned as infinite.

Inputs

InputMeaningUnitExample
Stotal room surface aream²120
Aabsorption area (a spectrum row)m²see below

Worked example

S = 120 m² with the absorption spectrum below:

Band (Hz)31.5631252505001000200040008000
A (m²)101012141820201816
Rc (m²)10.9110.9113.3315.8521.1824.0024.0021.1818.46

(e.g. at 500 Hz: 18/(1 − 18/120) = 21.18 m².)

Source

SRL, *Noise Control in Building Services* — the Sabine-based room constant relation.