- Formula
- Lp = Lw − 10·log₁₀(S/S₀); S = 4[(0.5A+r)(0.5B+r) + (0.5B+r)(C+r) + (C+r)(0.5A+r)]
- Output
- dB — attenuation correction, same value in every band
- Bands
- 31.5 Hz – 8 kHz (same value in every band)
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Estimates propagation loss from a rectangular plant item treated as a parallelipiped (box) source — the surface area of an imaginary box drawn at distance r around the source, used the same way as Conformal Area Propagation but with a box rather than a rounded-corner envelope.
Equation
where
and S₀ = 1 m².
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| A | source length | m | 3.6 |
| B | source width | m | 2.5 |
| C | source height | m | 1.7 |
| r | distance of propagation | m | 10 |
Worked example
A = 3.6 m, B = 2.5 m, C = 1.7 m, r = 10 m:
0.5A+r = 11.8, 0.5B+r = 11.25, C+r = 11.7 → S = 4(132.75 + 131.63 + 138.06) = 1609.7 m²
Correction = −10·log₁₀(1609.7) = −32.1 dB, applied equally to every band.
Source
General box-surface propagation relation for plant enclosures. No specific published standard is cited in the software.