Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

RT from Alpha

Formula
A = Σ(areaᵢ·αᵢ); Sabine T₆₀ = 0.161·V / A, or Eyring T₆₀ = 0.161·V / (−S·ln(1 − A/S)); V = floor × height, S = 2·floor + perimeter × height
Output
s — reverberation time per band
Bands
Follows the material α spectra (bands where every material with an area has an α)
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

Predicts a room's reverberation time band by band starting from its surface finishes: you give the room's floor area, perimeter and height, and one row per absorbing material with its area and absorption coefficient α in each band. The block works out the room volume, total surface area and total absorption, then applies the Sabine or Eyring equation (a Method select). Use it for design-stage RT predictions; if you already have the total absorption area per band, use RT from Sabines instead. Ribbon: Buildings → Reverberation → RT from Alpha.

Equation

A=∑iSi αiV=Afloor hS=2Afloor+P hA = \sum_i S_i\,\alpha_i \qquad V = A_{floor}\,h \qquad S = 2A_{floor} + P\,h
T60=0.161 VA (Sabine)T60=0.161 V−S ln⁡(1−A/S) (Eyring)T_{60} = \frac{0.161\,V}{A}\ \text{(Sabine)} \qquad T_{60} = \frac{0.161\,V}{-S\,\ln(1 - A/S)}\ \text{(Eyring)}

where Sᵢ and αᵢ are each material's area and absorption coefficient, A_floor the floor area, P the room perimeter and h the room height (S counts walls, floor and ceiling). The block also shows the Total Sabines A and the average absorption coefficient A/S per band in its workings.

A band is only computed when every material with a non-zero area has an α for it; until then that band is left blank (a missing α is never treated as zero absorption). For Eyring, A ≥ S gives 0 s.

Inputs

InputMeaningUnitExample
MethodSabine or EyringselectSabine
Absorbing materialsN material rows held inside the block (the insert dialog asks only for N, default 3; the rows start blank). Each row holds that material's area (Notes cell) and its α per band (band cells) — type them in, or bind the row to a published variablem² / —see below
Floor arearoom floor aream²10
Room perimeterroom perimeterm20
Room heightroom heightm2.7

Worked example

Floor 10 m², perimeter 20 m, height 2.7 m, so V = 10 × 2.7 = 27 m³ and S = 2 × 10 + 20 × 2.7 = 74 m². Three materials: carpet (10 m²), an acoustic ceiling (10 m²) and plastered walls (54 m²):

Band (Hz)125250500100020004000
Carpet α0.050.100.250.400.550.60
Ceiling α0.450.650.800.850.850.80
Walls α0.030.030.020.030.040.05
Total Sabines A (m²)6.629.1211.5814.1216.1616.70
T₆₀ Sabine (s)0.660.480.380.310.270.26
T₆₀ Eyring (s)0.630.450.350.280.240.23

(e.g. at 500 Hz: A = 10 × 0.25 + 10 × 0.80 + 54 × 0.02 = 11.58 m²; Sabine 0.161 × 27 / 11.58 = 0.38 s.)

Source

The Sabine and Eyring reverberation equations, with the room model (V = floor × height, S = 2 × floor + perimeter × height) taken from the Timbral reference spreadsheet's “Sabine / Eyring RT from alpha” sections. No specific published standard is cited in the software.