- Formula
- A_f = 4.47×10⁻³·(10^(0.025·L_N) − 1.15) + [0.4·10^((T_f + L_U)/10 − 9)]^α_f; L_p = (10/α_f)·log₁₀(A_f) − L_U + 94
- Output
- dB SPL (re 20 µPa) — fills a row with an equal-loudness contour
- Bands
- 1/3-octave centres 20 Hz – 12.5 kHz (fills whichever of these the sheet has)
- Standard / Source
- ISO 226:2003
- Access
- Curve fill
What it does
Fills the selected row with an ISO 226:2003 equal-loudness contour — the sound pressure level of a pure tone, heard in a free field from the front, that sounds as loud as a 1 kHz tone of the chosen loudness level (in phon). Useful as a reference overlay when judging how audible a low- or high-frequency component is. Pick Curves › Hearing › Equal Loudness ISO 226; the row is labelled “ISO 226 40 phon” and the loudness level sits in a yellow dropdown cell (20, 30, 40, 50, 60, 70, 80 or 90 phon) — change it and the row refills.
ℹ️ Available on every sheet kind. The standard tabulates the 29 one-third-octave centres from 20 Hz to 12.5 kHz; any band of your sheet outside that range (e.g. below 20 Hz on the low-frequency sheet) is left blank. Default: 40 phon. Values are written to one decimal place.
Equation
For each tabulated band, with the ISO 226 Table 1 parameters α_f (exponent), L_U (magnitude) and T_f (threshold of hearing):
where L_N is the loudness level in phon.
Worked example — 40 phon (octave sheet)
| Band (Hz) | 31.5 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|---|
| Level (dB) | 88.2 | 73.1 | 60.6 | 50.4 | 43.1 | 40.0 | 39.2 | 36.6 | 51.8 |
(By definition a contour reads its own phon value at 1 kHz.)
⚠️ ISO 226 states the contours as valid for 20–90 phon up to 4 kHz and for a narrower loudness range above that. Timbral does not clamp or blank values outside that validity: they are the standard's fitted formula extrapolated.
Source
ISO 226:2003 — Acoustics: Normal equal-loudness-level contours, equations (1)/(2) and Table 1.