Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

Sabines from RT (Sabine Absorption Area)

Formula
A = 0.161 · V / T₆₀
Output
m² — absorption per band
Bands
Follows the RT spectrum
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

The inverse of the Sabine equation: given a target (or measured) reverberation time and the room volume, it returns the total absorption required in each band. Useful for working out how much absorptive treatment a room needs to hit an RT target. Ribbon: Buildings → Reverberation → Sabines from RT (named “Sabine Absorption” before v0.8.0).

Equation

A=0.161 VT60A = \frac{0.161\,V}{T_{60}}

Inputs

InputMeaningUnitExample
T₆₀target reverberation time (a spectrum row)s0.8
Vroom volumem³200

Worked example

At a band where the target T₆₀ = 0.8 s, with V = 200 m³:

A=0.161×2000.8=40.25 m2A = \frac{0.161 \times 200}{0.8} = \mathbf{40.25\ m^2}

The calculation runs per band across the RT row; a band whose T₆₀ is blank or zero is left blank.

Source

Inverse Sabine relation. No specific published standard is cited in the software.