Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

Mass Law — Sound Reduction Index

Formula
R = 20·log₁₀(f·m) − C (C = 42 normal, 48 diffuse)
Output
dB (negative = attenuation)
Bands
1/1-octave 31.5 Hz – 8 kHz; 1/3-octave 25 Hz – 10 kHz (model valid 100 Hz – 3.15 kHz)
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

Estimates the sound reduction index of a simple single-leaf partition from its surface mass, using the mass law: heavier partitions and higher frequencies give more insulation, rising ~6 dB per doubling of mass or frequency. Ribbon: Buildings → Sound Insulation → Mass Law.

Equation

R=20 log⁡10(f m)−CR = 20\,\log_{10}(f\,m) - C

where m is the surface mass (kg/m²) and C is 42 for normal-incidence or 48 for diffuse (random-incidence) sound. The result is written negative (an attenuation). Diffuse is exactly 6 dB less than normal-incidence.

Inputs

InputMeaningUnitExample
msurface mass per unit areakg/m²25
Incidencenormal or diffuseselectdiffuse

Worked example

m = 25 kg/m², diffuse (C = 48):

Band (Hz)31.5631252505001000200040008000
R (dB)−9.93−15.95−21.90−27.92−33.94−39.96−45.98−52.00−58.02

(e.g. at 1 kHz: 20·log₁₀(1000×25) − 48 = 87.96 − 48 = 39.96, written −39.96 dB.)

ℹ️ The mass law is an idealisation — it ignores stiffness, the coincidence dip and damping, so real partitions depart from it, especially at high frequency. Bands outside the model's usual 100 Hz – 3.15 kHz range (on a 1/1-octave sheet: 31.5, 63 Hz, 4 and 8 kHz) are still filled, but carry a tooltip marking the value as an extrapolation.

Source

The idealised mass law. The 42 / 48 dB constants are not attributed to a specific published standard in the software.