NS 8178 Reverberation Time Limits

Formula
Figure 1: Tmf window (lower and upper limits) interpolated from NS 8178 Figure 1; Figure 2: band bound = chosen Tmf × T/Tm factor interpolated from Figure 2
Output
s — two rows per band: Upper bound and Lower bound
Bands
63 Hz – 4 kHz (octave bands; also written on 1/3-octave sheets at those centres)
Standard / Source
NS 8178:2014
Access
Toolbar block

What it does

Gives the permitted reverberation time range for a music room under the Norwegian standard NS 8178:2014. From the room's net volume, room type (rehearsal room or performance hall) and music type (quiet acoustical, loud acoustical or amplified) it shows the window the mid-frequency reverberation time Tmf (the mean of T₅₀₀ and T₁₀₀₀) must sit in. You then enter your chosen Tmf inside that window, and the block returns the upper and lower RT bounds in each octave band from 63 Hz to 4 kHz — the target envelope a measured or predicted RT curve should fall between. Ribbon: Buildings → Reverberation → NS 8178 RT Limits.

Equation

Figure 1 — the Tmf window: a lower and an upper limit for the room's volume, interpolated from NS 8178 Figure 1 for the room type and music type. The window for the current volume is shown in the Chosen Tmf row's label.

Figure 2 — the band bounds, applied to your chosen Tmf (not to the window's edges):

Tupper(f)=Tmf×Fupper(f)Tlower(f)=Tmf×Flower(f)T_{upper}(f) = T_{mf}\times F_{upper}(f) \qquad T_{lower}(f) = T_{mf}\times F_{lower}(f)

The T/Tm factors F are interpolated from NS 8178 Figure 2: one set for acoustical (quiet or loud) music in either room type, and separate sets for amplified music in rehearsal rooms and in performance halls.

No result is written until a Chosen Tmf is entered. A chosen Tmf outside the Figure 1 window, or a volume outside the range Figure 1 covers for that room and music type, is warned about in a tooltip on the result bands, never blocked.

Inputs

InputMeaningUnitExample
Vnet room volumem³500
Music typeQuiet acoustical, Loud acoustical or AmplifiedselectLoud acoustical
Room typeRehearsal room or Performance hallselectRehearsal room
Chosen Tmfyour mid-frequency RT, picked inside the window shown in the row labels1.0

Worked example

A 500 m³ rehearsal room for loud acoustical music. Figure 1 gives a Tmf window of 0.79 s to 1.13 s. Choosing Tmf = 1.0 s, the block writes an upper and a lower RT bound in each octave band from 63 Hz to 4 kHz — plot them with a measured or predicted RT curve to see whether it sits inside the envelope.

Source

NS 8178:2014 (Norwegian standard for acoustic criteria for rooms and spaces for music rehearsal and performance), Figure 1 (Tmf range against volume) and Figure 2 (T/Tm tolerance factors per octave band). Both figures are interpolated by Timbral.